T(P)GS-L6408XFTR
8 10/100/1000T + 2 10G Copper + 2 10G Fiber Q-ODC OM3 (w/8 PoE at/af) EN50155 OS3 Managed Ethernet Switch; WVI input

OVERVIEW
Lantech T(P)GS-L6408XFTR is a high performance OS3 Ethernet switch with 8 10/100/1000T + 2 auto-sensing 1G/2.5G/5G/10G Copper + 2 1G/10G SR/LR Fiber Q-ODC OM3. PoE model has 8 PoE 802.3af/at ports which provides advanced security function for network aggregation deployment.
Up to 8 PoE at/af ports w/advanced PoE management and PoE galvanic isolation; Ethernet power input galvanic isolation
Compliant with 802.3af/at standard, the PoE model is able to feed each PoE port up to 30 Watt at each PoE port for various IP PD devices. It supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.
Galvanic isolation between power input and Ethernet power system, also the PoE galvanic isolation provides insulation between the power input to PoE Ethernet ports, preventing cabling and grounding incidents from damaging the Ethernet switch. The efficiency of the galvanically decoupled voltage converters can reach above 90%.
Lantech OS3 Platform with complete L2 management and upgradable optional L3 & communication protocols
The switch runs Lantech OS3 platform which is powerful with complete Layer 2 management features and optional upgradable for future expansion, such as Layer 3 Lite, Layer 3, IEC61375-2-5 (ETBN), etc. To learn more about the Lantech OS3 Platform, please refer to Lantech OS3/OS4 platform
Enhanced cybersecurity features with IEC 62443-4-1 certification
Lantech OS3 platform is designed with high standard of cybersecurity to prevent the threats from network attack such as DDoS attacks. To ensure the safety and reliability of communication networks, Lantech develops our products under strict international security standard and is certified with IEC 62443-4-1 network security standard. To learn more about Lantech cybersecurity software solution, please refer to Lantech OS3/OS4 platform
Miss-wiring avoidance, node failure protection, Loop protection
The switch also embedded several features for strong and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, the switch being able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
User friendly GUI, Auto topology drawing, Enhanced Environmental Monitoring
The user-friendly UI, innovative auto topology drawing and topology demo makes the switch much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line. It supports enhanced environmental monitoring for actual input voltage, current, ambient temperature and total power load.
Built-in IEC 61375-3-4 ECN (Ethernet Consist Network) to work with IEC61375-2-5 TBN
Lantech OS3 Ethernet switches comply with IEC 61375-3-4 (ECN) standard. The support of Ethernet Consist Network allows interconnection between end devices located in single consist of train and interoperability with IEC61375-2-5 (TBN).
Editable configuration file; USB port for import/export configuration
The configuration file of the switch can be imported and edited with word processor for the following switches to configure with ease. The USB port can import/export the configuration from/to USB dongle and also to upgrade firmware from USB dongle. TFTP/HTTP firmware upgrade is supported.
Event log & message; 2DI + 2DO; Factory default pin
The switch provides 2DI and 2DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the outside alarm and switch will send alert information to IP network with traps. The factory reset pin can restore the setting back to factory default.
Optional smart bypass protection on dual 10G copper ports
The bypass relay is set to bypass the switch to the next one when power is off to prevent network disruption. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network lost. Optional smart bypass (one pair) can be activated when switch encounters power failure. (-BT model)
Dual WVI input with max PoE budget and Inrush current protection
The switch accept 16.8~137.5VDC (WVI model) dual input with Ethernet and PoE galvanic isolation and PoE model can feed 54V output for PoE feeding with 100W budget. The inrush current on initial power up can be limited lower than 10 x nominal current.
EN50155, EN45545-2; EN61373 compliance; Rugged design with high ESD protection
The switch is designed to meet with critical network environment with IP41 aluminum enclosure and M12 connectors for water proof. The switch passed serious tests under extensive Industrial EMI and Safety standards. With EN45545-2 Fire & Smoke and EN50155 verification, it is best switch for railway on-board/track side, vehicle, and mining applications. For more usage flexibilities, the switch supports wide operating temperature from -40°C to 70°C (85°C operation for 10min), which is compliant with the EN50155 Operating Temperature Range Requirement Class OT4.
*Future release
**Optional
SPECIFICATIONS
Hardware Specifications
Standards
|IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX
IEEE802.3ab 1000Base-T
IEEE802.3an 10Gbase-T
IEEE802.3ae 10Gbase-SR/LR
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet
Switch Architecture
|Back-plane (Switching Fabric): 96Gbps
| |Transfer Rate
|14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet port
Mac Address
|16K MAC address table
| |Jumbo frame
|10KB
| |Connectors
|10/100/1000T: 8 x ports M12 8-pole X-coded with Auto MDI/MDI-X function
1G/2.5G/5G/10G Copper: 2 x ports M12 8-pole X-coded with Auto MDI/MDI-X function
1G/10G FX: 2x ports Q-ODC OM3 with multi-mode/single-mode Fiber
Power Input connector: 1 x M12 4-pole Male S-coded
Reset/Console/USB: 1 x M12 8-pole Female A-coded
DIDO: 1 x M12 5-pole Female A-coded
Network Cable
|10Base-T: 4-pair STP Cat3 cable
100Base-TX: 4-pair STP Cat3/5 cable
1000Base-T: 4-pair STP Cat5/5e cable;
2.5G Copper: 4-pair STP Cat5e cable
10G Copper: 4-pair STP Cat6/6A cable
1G/10G fiber:
Multi-mode: 0 to 300 m, 850 nm (OM3 50/125 μm); Single-mode: 0 to 2 km, 1310 nm (9/125 μm)
LED
|Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red)
10/100/1000T Ethernet port: Link/Activity (Green), Speed (Green);
R.M. indicator (Green)
PoE: Link/Act (Green) (PoE model)
1G/2.5G/5G/10G copper: Link/Act (1G/2.5G/5G: Yellow; 10G: Orange)
1G/10G fiber: Link/Act (Orange)
DI/DO
|2 Digital Input (DI):
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output (DO): Open collector to 80 VDC, 50mA
Operating Humidity
|5% ~ 95% (Non-condensing)
| |Operating Temperature
|-40°C~70°C / -40°F~158°F (85°C operation for 10min.)
| |Storage Temperature
|-40°C~85°C / -40°F~185°F
| |Power Supply
|Dual DC input,16.8~137.5VDC
(PoE galvanic isolation for PoE models; Ethernet galvanic isolation for all models)
PoE Budget (PoE model)
|100W
Higher PoE budget can be applied upon request. **
PoE pin assignment (PoE model)
|M12 port #1~#8
support IEEE 802.3at/af End-point, Alternative A mode
Power Consumption
|40.5W exclude PoE load
| |Dimensions
|IP41 Aluminum alloy case 440mm(W)x44mm(H)x357.2mm(D)
| |Weight
|2.9kgs
| |Installation
|1U Rack mount design
| |EMI & EMS
|FCC,
EN 55032:2015,
EN 55024:2010,
EN IEC 61000-6-2,
EN IEC 61000-6-4,
IEC 61000-4-2 (ESD),
IEC 61000-4-3 (RS),
IEC 61000-4-4 (EFT),
IEC 61000-4-5 (Surge),
IEC 61000-4-6 (CS),
IEC 61000-4-8 (Magnetic field)
BS EN61000-4-2,
BS EN61000-4-3,
BS EN61000-4-4,
BS EN61000-4-5,
BS EN61000-4-6,
BS EN61000-4-8,
BS EN55032, BS EN55024
Stability Testing
|EN61373 (Shock and Vibration)
| |MTBF
|422,170hrs (standards: IEC 62380)
| |Verifications & report
|EN50155:2017/EN50121-3-2/EN50121-4/EN50125-1; EN60077/EN50124-1/EN55032; EN 45545-1, EN 45545-2 Fire & Smoke verification
| |Bypass**
|One pair bypass module on copper ports to pass to next switch in case of power failure and CPU fail
|Software Specifications
Lantech OS3 Platform
| |*Future release
**Optional

ORDERING INFORMATION
All model packages include M12 caps and wall mount bracket. All standard models are non-coating, optional coating models are available with –C model name. One pair bypass models are available with –BT model names.OPTIONAL ACCESSORIES - Software package
Please refer to Lantech OS3/OS4 platform
















